GE HealthCare's bedside X-ray AI can now check feeding tubes in kids
GE HealthCare says its on-device AI now detects feeding tubes and helps check their placement on X-rays for adult and, for the first time, pediatric patients.
This is the unflashy end of medical AI: one narrow job, on the machine already at the bedside, cleared by FDA. Note the performance numbers are GE's own testing.
On Tuesday, Nov. 17, GE HealthCare said the FDA had cleared Critical Care Suite 3.0. The clearance is a 510(k). That means the agency found the device substantially equivalent to one already on the market, which is a different bar from approving a drug. The FDA's public database lists the device as "Critical Care Suite with Enteric Tube Positioning AI Algorithm," number K253502, with a decision date of April 14, 2026. The company announced the clearance today. Enteric, here, means a feeding tube.
What the software does, in the company's words. AI built into the mobile X-ray machine detects a feeding tube and marks the tube's path, its tip, and its side port, the opening on the side of the tube. It also highlights the airway and the diaphragm, the muscle under the lungs, as reference points. A clinician can check the placement on the machine at the bedside. The company says that check does not need the internet or a cloud connection.
The new piece is age. Feeding-tube assessment now covers pediatric patients, children, which GE says is a first for the Critical Care Suite line. Earlier versions of the suite did not do this job for kids.
The performance numbers are the company's, from testing it points to in that same 510(k). GE says the software showed 99.2 percent sensitivity for finding a tube, and a 91.6 percent mean DICE score for localization. Sensitivity, here, is how often the software noticed a tube that was there. DICE is a score for how closely the AI's outline matched the outlines expert radiologists drew. The FDA database page for K253502 does not print those two percentages. They appear in GE's announcement.
The setting, as the release cites it. An IMV 2024 report, which GE footnotes, says 75 percent of mobile X-ray system use is in emergency departments and 51 percent is in intensive care units. Research GE cites estimates that 80 percent of intensive care patients get nutrition through a nasogastric or nasoenteric tube, a tube run through the nose into the stomach or past it. A tube that ends up in the wrong place can injure the patient. Those use figures and that 80 percent are the cited reports, as GE relays them, not a new count GE took this week.
Larry Boyd, vice president and general manager of global X-ray at GE HealthCare, said: "Critical care teams need to make timely clinical decisions in complex, rapidly changing environments when every minute counts." That quotation is his, in the release.
The picture is the Critical Care Suite screen for tube position. The panel on the left says the algorithm detected an endotracheal tube, a breathing tube, and puts it 0.5 centimeters from a marker on the X-ray. It is an example of the on-device interface. It is not a picture of the feeding-tube check this clearance covers.
In plain terms, GE says a mobile X-ray machine can now flag a feeding tube, including in children, without sending the image to the cloud. The FDA record shows the clearance decision is dated April 14, and the company talked about it on Nov. 17. The 99.2 percent and 91.6 percent figures are GE's own testing. The photo on this page is a breathing-tube example of the same screen, not a feeding tube.